Product Description

   Digital 4-20ma Output insert Flow Meter insertion magnetic flow meter 

Summary                                                                                                                     

 

     electromagnetic flow meter  with rs485 protocol ,as the product of long-term experience in the  field of flow nstrument,has the functionsof rapid response and output noise elimination,Its design and quality

 control systemhave guaranteed  the high accuracy and  reliability  of the product,   and the application of lining makes the electromagnetic flow meter applied more widely.

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

Features                                                                                                                         

1.The stability of flux measurement has been improved

2.Rapid response and high stability, even for highly concentrated serous fluid and fluid with low conductivity.

3.Electrode structure with high reliability

4.Lining and built-in grounding electrode are both applicable.

5.Diameter from 10mm to 3200mm

6.Both AC and DC power supplies are available.

7.Multi-functional Intelligent Converter.

8.When in power failure,EEPROM may protect the set parameters and accumulated values.

9.High-definition LCD Backlight Display.

 

 

Parameters                                                                                                                    

Aperture

10-3200

Excitation System

Bidirectional Constant Flow Squarewave Excitation

Installation Form

Integral or split

Lining

Chloroprene Rubber,PTFE

Material of Electrode

316L,HC,HB,Titanium,Tantalum,Platiniridium

Grounding

Built-in Grounding Electrode

Medium

Conductive Liquid

Grade of Accuracy

0.5,  1.0

Flow Velocity

≤15m/s

Flange of Pipe 

Connection

GB9119-2000 or GB9115-2000

Pipe connection

Flange Connection

Temperature of Medium

Chloroprene Rubber:-10-60℃: PTFE:-10-120℃

Rated Boltage

1.0MPa,  1.6MPa,  4MPa

Cable Interface

G1/2 Female Thread

Category of 

Shielding

IP65, IP68

Output Signal

4-20mACurrent,Pulse, Warning beyond upper and lower limits

Communication

RS485 Protocol

Display of Monitor

Transient Flow,Percentage,Flow Velocity,Forward and Reverse Integrated 

Flux and Total Integrated Flux

Power Supply

220VAC, 24VDC

Type of Application

General Type, Waterproof Type

 

 

 

Installation                                                                                                                     
Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

Conventional caliber flow range( Large caliber Advisory )                                        

Size(mm) Min flow m3/h Normal flow rate m3/h Max flow m3/h
DN15 0.06 0.19 3.18 6.36
DN20 0.11 0.33 5.65 11.31
DN25 0.17 0.53 8.83 17.67
DN32 0.28 0.86 14.47 28.94
DN40 0.45 1.35 22.61 45.23
DN50 0.71 2.12 35.35 70.68
DN65 1.19 3.58 59.72 119.45
DN80 1.81 5.42 90.47 180.95
DN100 2.82 8.48 141.37 282.74
DN125 4.41 13.25 220.85 441.71
DN150 6.36 19.08 318.08 636.17
DN200 11.31 33.92 565.48 1130.97
DN250 17.67 53.01 883.57 1767.14
DN300 25.44 76.34 1272.34 2544.69
DN350 34.63 103.91 1731.8 3463.6
DN400 45.23 135.71 2261.94 4523.89
DN450 57.25 171.76 2862.77 5725.55
DN500 70.68 212.05 3534.29 7068.58
DN600 101.78 305.36 5089.38 10178.76
DN700 138.54 415.63 6927.21 13854.42
DN800 180.95 542.86 9047.78 18095.57

 

 

Outline dimension                                                                                                           Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

Application area                                                                                                           

1. Drinking water supply, water supply, reservoir and pumping station etc.

2. Chemical acid, lye, conductive solution, cooling fluid, additives etc.

3. Drink water, beer, wine, alcohol, milk, yogurt, fruit juice, syrup, blood etc.

4. Refrigeration / air conditioning and refrigeration thermal measurement, or heat energy.

5. Sewage, industrial sewage discharge, sewage etc.

6.Control of metal industrial pump,cooling water and the flow of water.

7. The textile industry of water, pigments, chemicals, bleaching chemicals etc.

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

 

  Order sheet                                                                                                                   

Name

Specification code

Explanation

Instrument type

 

Intelligent electromagnetic flow meter

Diameter code

xxx

For example:100 represents DN100

Electrode form

1

Standard stationary type

 

 

 

 

Electrode material

0

Stainless steel(316L)

1

Platinum Pt

2

Hastelloy B(HB)

3

Tantalum Ta

4

Titanium Ti

5

Hastelloy C(HC)

 

 

 

Lining material

3

Chloroprene rubber

4

Polyurethane rubber

5

F4(PTFE) polytetrafluoroethylene

6

F46(FEP)polyperfluoroethylene-propylene

 

 

 

Rated pressure(MPa)

4.0

DN10-80

1.6

DN100-150

1.0

DN200-1000

0.6

DN1100-2000

0.25

DN2200

 

Operating temperature

E

<80℃

H

<120℃

Grounding

 

Built-in grounding electrode

Grade of  protection

0

IP65

1

IP68

Converter type

0

Integral type

1

Split type

Case material

0

Carbon steel

1

Stainless steel

Instrument flange

0

Carbon steel

1

Stainless steel

Installing timing flange

0

Withou

1

With

Power supply source

0

220VAC

1

24VDC

Instrument range

xxx

For example:(200)represents maximum 

fux corresponding to 20mA

Flow :200mm³/h

 

 

How to choose a right model

     The Flow meter model selection is very important in the application of instrument.The related information shows that in the practical application of instrument. 2/3 troubles are caused by incorrect selection of model and incorrect installation of instrument to which the special attention shall be paid.

1.Data Collection

    a.Name of medium.

   b.Maximum fulx and minimum flux.

   c.Maximum working prssure and temperature

2.The measured liquid shall have a certain conductivity,with conductivity ≥5us/cm

3.The actual maximum working pressure shall be less than rated working pressure of thef lowmeter

4.The maximum and minimum working temperatures shall meet the temperature requirement

   stipulated for flow meter

 Digital 4-20ma Output insert flow meter insertion magnetic flow meter

Work shop                                                                                                                       

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter


Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

 

 

 

 

Contact                                                                                                                            

Digital 4-20ma Output insert flow meter insertion magnetic flow meter

Contact us if you need more details on Cheap Flow Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Magnetic Flow Meter、Sewage Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Flow Meter > Electromagnetic Flowmeter